HP Elitepad 1000 G2 , BIOS Application Error (501)

While imaging HP Elitepad 1000 G2 I ran into the problem when trying to enter BIOS. Elitepad was hooked to docking station and connected to keyboard. When I pressed F2 I got the following error

The HP BIOS location selected is corrupt or missing.Please install the application and try again
BIOS Application error (501)

1000G2_0

 

Upon research I found out that this is an expected error for UEFI secure bios and I need to create a extra thumb drive to boot this tablet into BIOS.

Here is download link to HP hardware diagnostics tool .This tool lets you enter BIOS and provide other diagnostics utilities as well.

After you download it the HP hardware diagnostics utility , You can install it on USB Drive . Ensure that USB drive has no data and is formatted . This utility will rename the USB drive to HP_TOOLS

1000G2_1

 

Click Next

 

1000G2_2

 

Accept the licence agreement, Click next

1000G2_3

Wizard will decompress it to temp location

1000G2_4

 

Click Next

1000G2_5

 

Select USB Drive

 

1000G2_6

 

Files are extracted and program is ready to install , Click next

1000G2_7

 

Beginning install

 

1000G2_8

 

Installation Wizard ask to create HP_TOOLS volume label.

 

1000G2_9

 

This completes the installation

 

1000G2_10

 

This is what is inside the boot media. Main folder Hewlett-Packard and three sub folders

 

1000G2_12

 

Now connect the newly created HP Diagnostic media to HP Elitepad 1000 G2 docking station

Boot up the tablet while pressing the volume key on tablet and press F2

1000G2_13

This takes you to BIOS , Now you can press F10 or navigate using keyboard to enter BIOS

1000g2_14

 

This concludes the post